/DoubleMu/Run2011A-v1/RAW, CMS collaboration
Cite as: CMS collaboration (2019). DoubleMu primary dataset sample in RAW format from RunA of 2011 (from /DoubleMu/Run2011A-v1/RAW). CERN Open Data Portal. DOI:10.7483/OPENDATA.CMS.BRGY.WRYN
Dataset Collision CMS 7TeV CERN-LHC
A sample from DoubleMu primary dataset in RAW format from RunA of 2011. Run range [163371,163588].
This dataset contains selected runs from 2011 RunA. The list of validated lumi sections, which must be applied to all analyses on events reconstructed from these data, can be found in
CMS list of validated runs Cert_160404-180252_7TeV_ReRecoNov08_Collisions11_JSON.txt
Events stored in this primary dataset were selected because of the presence of at least two high-energy muon in the event.
Data taking / HLT
The collision data were assigned to different RAW datasets using the following HLT configuration.
HLT trigger paths
The possible HLT trigger paths in this dataset are:
HLT_DoubleMu3
HLT_DoubleMu45
HLT_DoubleMu4_Acoplanarity03
HLT_DoubleMu5
HLT_DoubleMu5_Acoplanarity03
HLT_DoubleMu5_IsoMu5
HLT_DoubleMu6
HLT_DoubleMu6_Acoplanarity03
HLT_DoubleMu7
HLT_DoubleMu7_Acoplanarity03
HLT_L1DoubleMu0
HLT_L2DoubleMu0
HLT_L2DoubleMu23_NoVertex
HLT_L2DoubleMu30_NoVertex
HLT_L2DoubleMu30_NoVertex_dPhi2p5
HLT_L2DoubleMu35_NoVertex
HLT_L2DoubleMu45_NoVertex
HLT_Mu13_Mu8
HLT_Mu17_Mu8
HLT_Mu17_TkMu8
HLT_Mu8_Jet40
HLT_TripleMu5
During data taking all the runs recorded by CMS are certified as good for physics analysis if all subdetectors, trigger, lumi and physics objects (tracking, electron, muon, photon, jet and MET) show the expected performance. Certification is based first on the offline shifters evaluation and later on the feedback provided by detector and Physics Object Group experts. Based on the above information, which is stored in a specific database called Run Registry, the Data Quality Monitoring group verifies the consistency of the certification and prepares a json file of certified runs to be used for physics analysis. For each reprocessing of the raw data, the above mentioned steps are repeated. For more information see:
CMS data quality monitoring: Systems and experiences
The CMS Data Quality Monitoring software experience and future improvements
The CMS data quality monitoring software: experience and future prospects
These data are in RAW format and not directly usable in analysis. The reconstructed data reprocessed from these RAW data are included in the data of this record. The reconstruction step can be repeated with the configuration file below and the resulting AOD has been confirmed to be identical with the original one with comparison code available in Validation code to plot basic physics objects from AOD
The open data are released under the Creative Commons CC0 waiver. Neither CMS nor CERN endorse any works, scientific or otherwise, produced using these data. All releases will have a unique DOI that you are requested to cite in any applications or publications.